Error J-1710 Follow
Classification
Paper feed conveyance
JAM Code
J-1710
Cause
During operation:
(PF-602m)
Within a specified period of time after the horizontal conveyance sensor/2 (PS19) of PF, the intermediate conveyance sensor/1 (PS12) does not become active.
(PF-707m)
Within a specified period of time after the horizontal conveyance sensor/3 (PS21) of PF, the intermediate conveyance sensor/1 (PS12) does not become active.
Correction
Open the PF front door, the PF vertical conveyance door, the horizontal conveyance door/Rt, and the horizontal conveyance door/Lt. Then remove any jammed paper.