Error Code Solution: C-3102 Follow
Problem:
Error C-3102 (Fuser Error)
Classification:
Main Body: Motor Abnormality
Cause:
During the pressing operation: Within a specified period of time after the fusing pressure release motor (M47) becomes active, the fusing pressure position sensor/2 (PS26) or the fusing pressure position sensor/3 (PS25) does not become active. During the release operation: Within a specified period of time after M47 becomes active, the fusing pressure position sensor/1 (PS24) does not become active. (Broken actuator No 5. Part no. A50U744700 Pressure Actuator /1)
Solution:
- Check the fusing unit,
- Check IO Check (47-05) of PS24, IO Check (47-06) of PS26, IO Check (47-07) of PS25 and the operation of PS24, PS26, PS25, and repair it when there is any abnormality.
- Check the flag actuator if broken on the bottom part of the fusing. please see images for reference. replace the flag actuator.
Please see the image for the proper placement of the parts and reference