Error Code: C-3803 Follow
Classification
Main body: Fusing roller/Lw central section low temperature abnormality
Cause
During the fusing idling or printing, the fusing temperature sensor/5 (TH5) detects that the temperature is less than 50℃ continuously for a specified period of time. However, the detection is not performed in the monochrome energy-save mode.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
• Fusing unit
• Printer control board (PRCB)
• AC drive board (ACDB)
• Fusing heater lamp/4 (L4)
• Fusing temperature sensor/5 (TH5)
• Thermostat/3 (TS3)
Correction
Solution
1. Check the connection between the rear side connector of the fusing unit and the main body side connector, and repair it when there is any abnormality.
2. Check the connector connection between TH5 and PRCB, and the wiring. Then repair it when there is any abnormality. (Wiring diagram: Main body (1/5): 9-H)
3. Check the connector connection between TS3 and ACDB, and the wiring. Then repair it when there is any abnormality. (Wiring diagram: Main body (1/5): 8-E)
4. Check the conduction of TS3, and repair it when there is any abnormality.
5. Check the installation condition of L4, and the activation or deactivation with the IO Check (45-00) and others. Then repair it when there is any abnormality. (Wiring diagram: Main body (1/5): 3-J)
Note
▪ The output check on the IO check mode has restrictive conditions. Check the IO check mode list before the output check.
6. Check the installation condition of TH5 and the temperature of the IO Check (45-15), and adjust it when there is any abnormality. (Wiring diagram: Main body (1/5): 3-K)
7. Replace TH5.
8. Replace TS3.
9. Replace L4.
10. Replace ACDB.
11. Replace PRCB.