Error Code: C-0116 Follow
Classification
PF: PF-707m (1st tandem) horizontal conveyance motor abnormality
Cause
An error signal is detected while the horizontal conveyance motor (M3) is active.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
• Horizontal conveyance motor (M3)
• PF drive board (PFUDB)
Correction
Press the help key to activate and deactivate the sub power switch (SW2) of the main body.
Note
▪ When you isolate the faulty part, the limited use is available.
▪ The message "Please call service" and "Press [Help] to disengage" are displayed alternately on the touch panel.
▪ When you press the help key, the message "Please turn on power again" is displayed on the touch panel.
Solution
1. Check the connector connection between PFUDB and M3 and the wiring. Then repair it when there is any abnormality.
2. Check IO Check (28-11) of M3 and the coupling of the gear, repair or replace it when there is any abnormality, and then replace PFDB
(Wiring diagram: PF (1/2): 4-F)
3. Replace M3.
4. Replace PFUDB.
Faulty part isolation DIPSW
DIPSW35-0
DIPSW35-1
DIPSW35-2
Control during the detachment
The Paper feed in the tray 3-5 is unavailable.