Error Code: C-0001 Follow
Code
C-0001
Classification
Main body: Communication error
Cause
Communication error between the printer control board (PRCB) and the PF drive board (PFDB), PFU drive board (PFUDB) or the LU drive board (LUDB).
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Printer control board (PRCB)
- PF drive board (PFDB)
- PFU drive board (PFUDB)
- LU drive board (LUDB)
Correction
Deactivate and activate the sub power switch (SW2) of the main body.
Note
- The message "Please turn on power again" is displayed on the touch panel.
Solution
- Deactivate the sub power switch and the main power switch, and then unplug the power plug. Then Restart the main body after 10 seconds.
- PF-602m: Check the connector connection between PRCB and PFDB, and the wiring. Then repair it when there is any abnormality.
- PF-707m: Check the connector connection between PRCB and PFUDB, and the wiring. Then repair it when there is any abnormality.
- LU-202m: Check the connector connection between PRCB and LUDB, and the wiring. Then repair it when there is any abnormality.
- LU-202XLm: Check the connector connection between PRCB and LUDB, and the wiring. Then repair it when there is any abnormality.
- Replace PRCB.
- PF-602m: Replace PFDB.
- PF-707m: Replace PFUDB.
- LU-202m: Replace LUDB.
- LU-202XLm: Replace LUDB.
- Note
- Be careful not to confuse the LUDB of LU-202m with the LUDB of LU-202XLm.
Faulty part isolation DIPSW
Control during the detachment