Error Code: C-0114 Follow
Classification
PF: PF-707m (1st tandem) loop motor abnormality
Cause
An error signal is detected while the loop motor/2 (M6) is activated.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
• Loop motor/2 (M6)
• PF drive board (PFUDB)
Correction
Press the help key to activate and deactivate the sub power switch (SW2) of the main body.
Note
▪ When you isolate the faulty part, the limited use is available.
▪ The message "Please call service" and "Press [Help] to disengage" are displayed alternately on the touch panel.
▪ When you press the help key, the message "Please turn on power again" is displayed on the touch panel.
Solution
1. Check the connector connections between PFUDB and M6, and the wiring. Then repair it when there is any abnormality.
2. Check IO Check (26-12) and others of M6 and the coupling of the gear, and repair or replace it and replace PFDB when there is any
abnormality (Wiring diagram: PF (1/2): 22-K)
3. Replace M6.
4. Replace PFUDB.
Faulty part isolation DIPSW
DIPSW35-0
DIPSW35-1
DIPSW35-2
Control during the detachment
The Paper feed in the tray 3-5 is unavailable.