Error Code: C-0326 Follow
Classification
PF: PF-707m paper leading edge separation fan abnormality
Cause
An error detection signal is detected continuously for a specified period of time while the paper leading edge separation fan/Fr1 (FM9) and the paper leading edge separation fan/Rr1 (FM10) are ON.
An error detection signal is detected continuously while you retry power feed several times.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
• Paper leading edge separation fan/Fr1 (FM9), paper leading edge separation fan/Rr1 (FM10)
• PF drive board (PFUDB)
Solution
1. Check the connector connections between PFUDB and FM9, FM10, and the wiring. Then repair it when there is any abnormality.
2. Rotate FM9 or FM10 by hand or the IO Check (29-42). Then repair or replace it when there is any abnormality. (Wiring diagram: PF (1/2): 4-K)
3. Replace FM9 or FM10, and PFUDB at the same time.