Error Code: C-0136 Follow
Classification
PF-707m (1st tandem): Registration motor abnormality
Cause
When the registration motor (M11) is active, an error detection signal is detected.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
• PFU drive board (PFUDB)
• Registration motor (M11)
Solution
1. Execute the IO Check (28-36) of the registration motor (M11) (PF 1st tandem: 770 mm/s).
2. When the result of the IO Check in the step 1 is normal, M11 is not abnormal. Go on to step 4.
For details of IO check results, refer to "Table 1: Result check."
3. Check the connector connection, CN194 of PFUDB, CN436 (relay connector), CN439 (relay connector), CN371 of M11, and the wirings between PFUDB and M11. Then repair it when there is any abnormality.
4. Check the coupling of the gear of M11, and repair or replace it when there is any abnormality.
5. Replace M11.
6. Replace PFUDB.