Error Code: C-0130 Follow
Classification
PF: PF-707m (1st tandem) roller pressure release motor abnormality
Cause
When the roller pressure release motor (M10) is active, an error signal is detected.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
• Roller pressure release motor (M10)
• PF drive board (PFUDB)
Correction
Note
▪ The message "Please call service" is displayed on the panel.
Solution
1. Check the connector connection between PFUDB and M10 and the wiring. Then repair it when there is any abnormality.
2. Check IO Check (28-16) and others of M10 and the coupling of the gear, and repair or replace it when there is any abnormality. (Wiring diagram: PF (1/2): 22-B)
3. Replace M10.
4. Replace PFUDB.