Error Code: C-1144 Follow
Classification
FS: FS-532 abnormality
Cause
The paper exit alignment plate home sensor (PS101) does not become active within a specified period of time after the paper exit alignment plate motor (M101) becomes active.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
• FNS control board (FNSCB)
• Paper exit alignment plate motor (M101)
• Paper exit alignment plate home sensor (PS101)
Correction
Press the help key to activate and deactivate the sub power switch (SW2) of the main body.
Note
▪ When you isolate the faulty part, the limited use is available.
▪ The message "Please call service" and "Press [Help] to disengage" are displayed alternately on the touch panel.
▪ When you press the help key, the message "Please turn on power again" is displayed on the touch panel.
Solution
1. Check the connector connection between FNSCB and M101, CN31 of FNSCB, CN184 (Relay connector), CN112 of M101, and the wiring. Then repair it when there is any abnormality.
2. Check the connector connection between FNSCB and PS101, CN47 of FNSCB, CN97 (Relay connector), CN160 of PS101, and the wiring. Then repair it when there is any abnormality.
3. Check the IO Check (72-18) and others of M101 and the coupling of the gear, and repair it when there is any abnormality.
Note
▪ The output check on the IO check mode has restrictive conditions. Check the IO check mode list before the output check.
4. Check the IO Check (72-17) of PS101 or the operation, and repair it when there is any abnormality.
5. Replace PS101.
6. Replace M101.
7. Replace FNSCB.
Faulty part isolation DIPSW
DIPSW6-4
Control during the detachment
FS main tray and stapling are not available