Error Code: C-7205 Follow
Classification
Main body: Conveyance drive board ICP blowout
Cause
When a specified period of time elapses after the power becomes active, an error detection signal of ICP4 is detected continuously for a specified period of time.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
• Conveyance drive board (CDB)
Solution
1. Check the connector connection between CDB and the reverse exit motor (M43), CN170 of CDB, CN445 of M43, and the wiring. Then
repair it when there is any abnormality.
2. Replace CDB.