Error Code: C-0209 Follow
Classification
PF: PF-602m or PF-707m paper lift motor abnormality
Cause
The power supply line fuse for the paper lift motor/1 (M2: PF-602m, M7: PF-707m) becomes blown.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
• PF drive board (PFUDB)
• The paper lift motor/1 (M2: PF-602m, M7: PF-707m)
Correction
Press the help key to activate and deactivate the sub power switch (SW2) of the main body.
Note
▪ When you isolate the faulty part, the limited use is available.
▪ The message "Please call service" and "Press [Help] to disengage" are displayed alternately on the touch panel.
▪ When you press the help key, the message "Please turn on power again" is displayed on the touch panel.
Solution
1. PF-602m: Check the connector connection and the wiring between PFDB and M2, and repair it when there is any abnormality.
PF-707m: Check the connector connection and the wiring between PFUDB and M7, and repair it when there is any abnormality.
2. PF-602m: Check IO Check (23-07) of M2 and the coupling of the gear, and repair or replace it when there is any abnormality. (Wiring diagram: PF-602m: 11-U)
PF-707m: Check the IO Check (23-10) of M7 and the coupling of the gear, and repair or replace it when there is any abnormality. (Wiring diagram: PF-707m (1/2): 1-M)
3. PF-602m: Replace M2 and PFDB at a time.
PF-707m: Replace M7 and PFUDB at a time.
Faulty part isolation DIPSW
DIPSW35-0
Control during the detachment
Paper feed in the PF upper tray is unavailable.