Error Code: C-3513 Follow
Classification
Main body: Fusing temperature sensor/1 wiring disconnection abnormality
Cause
The fusing unit becomes inactive because the door opens or closes when the machine starts warm-up or it is in the low power mode. Then, the AD value of the fusing temperature sensor/1 (TH1) changes abnormally within the specified period of time after the fusing unit becomes active again, and the wiring disconnection is detected.
Measures to take when an alert occurs The main body and the option stop immediately.
Estimated abnormal parts
• Fusing unit
• Printer control board (PRCB)
• Fusing heater lamp/1 (L1)
• Fusing temperature sensor/1 (TH1)
• Thermostat/1 (TS1)
Correction
Solution
1. Check the connection between the rear side connector of the fusing unit and the main body side connector, and repair it when there is anyabnormality.
2. Check the connector connections between TH1 and PRCB, and the wiring. Then repair it when there is any abnormality. (Wiring diagram: Main body (1/5): 8-H)
3. Check the conduction of TS1, and repair it when there is any abnormality.
4. Check the activation and deactivation by the L1 installation condition or the IO Check (45-11), repair it when there is any abnormality. (Wiring diagram: main body (1/5): 2-F, 2-G)
Note
▪ The output check on the IO check mode has restrictive conditions. Check the IO check mode list before the output check.
5. Check the installation condition of TH1 and the temperature of IO Check (45-00) and others and adjust it when there is any abnormality.
(Wiring diagram: Main body (1/5): 3-H)
6. Replace TH1.
7. Replace TS1.
8. Replace the fusing heater lamp assy/Up.
9. Replace PRCB.