Error Code: C-1702 Follow
Code
C-1702
Classification
RU-518m: RU-518m abnormality (1st device)
Cause
The conveyance path switch motor (M102) does not stop even after a specified period of time after M102 starts the operation.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Conveyance path switch sensor (PS102)
- Conveyance path switch motor (M102)
- RU control board (PCB1)
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
- Check the IO Check (66-12) of PS102 and M102 and the coupling of the gear. Then repair or replace them when there is any abnormality.
- Check the connector connection between PCB1 and PS102, and the wiring. Then, repair it when there is any abnormality. (Wiring diagram: RU-518m/HM-103: 14-M)
- Check the connector connection between PCB1 and M102, and the wiring. Then, repair it when there is any abnormality. (Wiring diagram: RU-518m/HM-103: 12-M)
- Replace PS102.
- Replace M102.
- Replace PCB1. (Connector layout drawing in board: RU control board (PCB1))
Faulty part isolation DIPSW
Control during the detachment