Error Code: C-0301 Follow
Code
C-0301*
Classification
Main body: Fan abnormality
Cause
When the cyclone exhaust fan (FM22) is active, an error detection signal of FM22 is detected continuously for a specified period of time.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Printer control board (PRCB)
- Cyclone exhaust fan (FM22)
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
- Check the connector connection and the wiring between PRCB and FM22, and repair it when there is any abnormality.
- Rotate FM22 or IO Check (42-06) manually, and repair or replace it when there is any abnormality. (Wiring diagram: Main body (1/5): 18-F)
- Replace FM22.
- Replace PRCB.
Faulty part isolation DIPSW
Control during the detachment