Error Code: C-0230 Follow
Classification
Main body: Motor abnormality
Cause
When the reverse exit pressure home sensor (PS9) is active: Within a specified period of time after the decurler pressure release motor (M37) becomes active, PS9 does not become active. When PS9 is not active: Within a specified period of time after M37 becomes active, PS9 does not become active.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
• Conveyance drive board (CDB)
• Decurler pressure release motor (M37)
• Reverse exit pressure home sensor (PS9)
Correction
Note
▪ The message "Please call service" is displayed on the panel.
Solution
1. Check that the front door is closed properly, and repair it when there is any abnormality.
2. Check the reverse paper exit section, and repair it when there is any abnormality.
3. Check the drive gear system in the reverse paper exit section, and repair it when there is any abnormality.
4. Check the connector connection and the wiring between CDB, M37 and PS9, and repair it when there is any abnormality.
5. Check the IO Check (86-18) and others of M37 or the coupling of the gear, and repair it when there is any abnormality. (Wiring diagram: Main body (1/5): 19-O)
6. Check the IO Check (86-18) and others and the operation of PS9, and repair or replace it when there is any abnormality. (Wiring diagram: Main body (1/5): 21-O)
7. Replace PS9.
8. Replace M37.
9. Replace CDB.
10. Replace M37 and CDB at a time.