Error Code: C-0314 Follow
Classification
PF: PF-602m fan abnormality
Cause
An error detection signal of FM6 is detected continuously for a specified period of time while the paper feed assist fan/Rr21 (FM6) is ON.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
• PF drive board (PFDB)
• Paper feed assist fan/Rr21 (FM6)
Correction
Note
▪ The message "Please call service" is displayed on the panel.
Solution
1. Check the connector connection between PFDB and FM6, and the wiring. Then repair it when there is any abnormality.
2. Rotate FM6 with the IO Check (29-10) or by hand. Then repair or replace it when there is any abnormality. (Wiring diagram: PF: 19-K)
3. PF-707: Replace FM6 and PFDB at a time.