Error Code: C-0333 Follow
Classification
PF: PF-707m paper feed assist fan abnormality
Cause
An error detection signal is detected continuously for a specified period of time while the paper feed assist fan/Rr2 (FM16) is active. An error detection signal is detected continuously while you retry power feed several times.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
• Paper feed assist fan/Rr2 (FM16)
• PF drive board (PFUDB)
Correction
Note
▪ The message "Please call service" is displayed on the panel.
Solution
1. Check the connector connections between PFUDB and FM16, and the wiring. Then repair it when there is any abnormality.
2. Rotate FM16 by hand or the IO Check (29-45). Then repair or replace it when there is any abnormality. (Wiring diagram: PF (1/2): 12-K)
3. Replace FM16 and PFUDB at the same time.