Error Code: C-0339 Follow
Classification
PF: PF-707m dehumidifier fan abnormality
Cause
An error detection signal is detected continuously for a specified period of time while the dehumidifier fan/Rt2 (FM23) and the dehumidifier fan/Lt2 (FM24) are ON.
An error detection signal is detected continuously while you retry power feed several times.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
• Dehumidifier fan/Rt2 (FM23), dehumidifier fan/Lt2 (FM24)
• PF drive board (PFUDB)
Correction
Note
▪ The message "Please call service" is displayed on the panel.
Solution
1. Check the connector connections between PFUDB and FM23, FM24, and the wiring. Then repair it when there is any abnormality.
2. Rotate FM23, FM24 by hand or the IO Check (42-45). Then repair or replace it when there is any abnormality. (Wiring diagram: PF (2/2): 8-D, 8-C)
3. Replace FM23 or FM24, and PFUDB at the same time.