Error Code: C-0405 Follow
Classification
PF: PF-602m or PF-707m power source abnormality
Cause
12 V DC is not supplied to PF.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- PF drive board (PFDB, PFUDB)
- DC power supply/1 (DCPS1) (AC57V130##, AC58V130## (C4070: Japan))
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
- PF-602m: Check the connector connection between PFDB and DCPS1, and the wiring. Then repair it when there is any abnormality.
- PF-707m: Check the connector connection between PFUDB and DCPS1, and the wiring. Then repair it when there is any abnormality.
- PF-602m: Replace PFDB.
- PF-707m: Replace PFUDB.
- PF-602m: Replace DCPS1.
- PF-707m: Replace DCPS1.
- PF-602m: Replace PFDB and DCPS1 at a time.
- LU-707m: Replace PFUDB and DCPS1 at the same time.
Faulty part isolation DIPSW
Control during the detachment