Error Code: C-0411 Follow
Classification
PF: PF-602m fan heater abnormality
Cause
Fan heater/Up (DH3) low temperature abnormality
The temperature sensor/3 (TEMS/3) detects the prescribed or lower value continuously for a specified period of time.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- PF drive board (PFDB)
- AC drive board in PF (ACDB)
- Fan heater/Up (DH3)
- Temperature sensor/3 (TEMS/3)
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
- Check the connection between ACDB and the noise filter of PF.
- Check the connector connection between PFDB and TEMS/3, and the wiring. Then repair it when there is any abnormality.
- Check the connector connection between ACDB and DH3, and the wiring. Then repair it when there is any abnormality.
- Check the connector connection between PFDB and ACDB, and the wiring. Then repair it when there is any abnormality.
- Check the temperature and the installation condition of DH3 and the installation condition of TEMS/3, and repair or replace it when there is any abnormality. (Wiring diagram: PF: 22-D, 25-D)
- Replace TEMS3.
- Replace DH3.
- Replace ACDB.
- Replace PFDB.
Faulty part isolation DIPSW
Control during the detachment