Error Code: C-0412 Follow
Classification
PF: PF-602m fan heater abnormality
Cause
Fan heater/Lw (DH4) low temperature abnormality
The temperature sensor/4 (TEMS/4) detects the prescribed or lower value continuously for a specified period of time.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- PF drive board (PFDB)
- AC drive board in PF (ACDB)
- Fan heater/Lw (DH4)
- Temperature sensor/4 (TEMS/4)
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
- Check the connection between ACDB and the noise filter of PF.
- Check the connector connection and the wiring between PFDB and TEMS/4, and repair it when there is any abnormality.
- Check the connector connection and the wiring between ACDB and DH4, and repair it when there is any abnormality.
- Check the connector connection and the wiring between PFDB and ACDB, and repair it when there is any abnormality.
- Check the temperature and the installation condition of the DH4 and the installation condition of the TEMS/4, and repair or replace it when there is any abnormality. (Wiring diagram: PF: 21-F, 24-F)
- Replace TEMS/4.
- Replace DH4.
- Replace ACDB.
- Replace PFDB.
Faulty part isolation DIPSW
Control during the detachment