Error Code: C-1102 Follow
Classification
FS: FS-532 abnormality
Cause
The main tray up down motor (M301) does not become inactive even when a specified period of time elapses after it starts operations. Alternatively, it operates for more than the allowed time at a speed out of the specified one.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- FNS control board (FNSCB)
- Main tray up down motor (M301)
- Tray upper limit LED (LED1)
- Main tray upper limit sensor (PS051)
Correction
Press the help key to activate and deactivate the sub power switch (SW2) of the main body.
Note
- When you isolate the faulty part, the limited use is available.
- The message "Please call service" and "Press [Help] to disengage" are displayed alternately on the touch panel.
- When you press the help key, the message "Please turn on power again" is displayed on the touch panel.
Solution
- Check the tray up and down section, and clean or repair it when there is any abnormality.
- Check the connector connection between FNSCB and M301, CN38 of FNSCB, CN111 of M301, and the wiring. Then repair it when there is any abnormality.
- Check the connector connection between FNSCB and LED1, CN46 of FNSCB, CN79 (Relay connector), CN140 of LED1, and the wiring. Then repair it when there is any abnormality.
- Check the connector connection between FNSCB and PS051, CN46 of FNSCB, CN154 of PS051, and the wiring. Then repair it when there is any abnormality.
- Check the IO Check (72-11), LED emission, and the light-receiving path of PS051, and repair it when there is any abnormality.
- Check the IO Check (72-15) of M301 and the coupling of the gear, and repair it when there is any abnormality.
- Replace LED1 and PS051.
- Replace M301.
- Replace FNSCB.
Faulty part isolation DIPSW
DIPSW6-4
Control during the detachment
FS main tray and stapling are not available