Error Code: C-1103 Follow
Classification
FS: FS-532 abnormality
Cause
The stacker alignment home sensor (PS117) does not become active within a specified period of time after the home position search operation of the stacker alignment motor (M117) starts.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- FNS control board (FNSCB)
- Stacker alignment motor (M117)
- Stacker alignment home sensor (PS117)
Correction
Press the help key to activate and deactivate the sub power switch (SW2) of the main body.
Note
- When you isolate the faulty part, the limited use is available.
- The message "Please call service" and "Press [Help] to disengage" are displayed alternately on the touch panel.
- When you press the help key, the message "Please turn on power again" is displayed on the touch panel.
Solution
- Check the alignment section, and clean or repair it when there is any abnormality.
- Check the connector connection between FNSCB and M117, CN30 of FNSCB, CN133 (Relay connector), CN109 of M117, and the wiring. Then repair it when there is any abnormality.
- Check the connector connection between FNSCB and PS117, CN44 of FNSCB, CN193 (Relay connector), CN152 of PS117, and the wiring. Then repair it when there is any abnormality.
- Check the IO Check (72-09) and others of M117 and the coupling of the gear, and repair it when there is any abnormality.
- Note
- The output check on the IO check mode has restrictive conditions. Check the IO check mode list before the output check.
- Check the IO Check (72-09) of PS117 or the operation, and repair it when there is any abnormality.
- Replace PS117.
- Replace M117.
- Replace FNSCB.
Faulty part isolation DIPSW
DIPSW6-3
Control during the detachment
The use of the staple is unavailable