Error Code: C-1106 Follow
Classification
FS: FS-532 abnormality
Cause
The stapler movement home sensor (PS116) does not become active within a specified period of time after the home position search operation of the stapler movement motor (M116) starts.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- FNS control board (FNSCB)
- Stapler movement motor (M116)
- Stapler movement home sensor (PS116)
Correction
Press the help key to activate and deactivate the sub power switch (SW2) of the main body.
Note
- When you isolate the faulty part, the limited use is available.
- The message "Please call service" and "Press [Help] to disengage" are displayed alternately on the touch panel.
- When you press the help key, the message "Please turn on power again" is displayed on the touch panel.
Solution
- Check the stapler movement section, and clean or repair it when there is any abnormality.
- Check the connector connection between FNSCB and M116, CN34 of FNSCB, CN136 (Relay connector), CN114 of M116, and the wiring. Then repair it when there is any abnormality.
- Check the connector connection between FNSCB and PS116, CN43 of FNSCB, CN134 (Relay connector), CN162 of PS116, and the wiring. Then repair it when there is any abnormality.
- Check the IO Check (72-24) and others of M116 and the coupling of the gear, and repair it when there is any abnormality.
- Check the IO Check (72-19) of PS116 or the operation, and repair it when there is any abnormality.
- Replace PS116.
- Replace M116.
- Replace FNSCB.
Faulty part isolation DIPSW
DIPSW6-3
Control during the detachment
The use of the staple is unavailable