Error Code: C-1113 Follow
Classification
FS: FS-532 abnormality
Cause
The stacker rear stopper home sensor (PS112) does not become active within a specified period of time after the home position search operation of the stacker movement motor (M112) starts.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- FNS control board (FNSCB)
- Stacker movement motor (M112)
- Stacker rear stopper home sensor (PS112)
Correction
Press the help key to activate and deactivate the sub power switch (SW2) of the main body.
Note
- When you isolate the faulty part, the limited use is available.
- The message "Please call service" and "Press [Help] to disengage" are displayed alternately on the touch panel.
- When you press the help key, the message "Please turn on power again" is displayed on the touch panel.
Solution
- Check the stapler rotation section, and clean or repair it when there is any abnormality.
- Check the connector connection between FNSCB and M112, CN30 of FNSCB, CN133 (Relay connector), CN119 of M112, and the wiring. Then repair it when there is any abnormality.
- Check the connector connection between FNSCB and PS112, CN44 of FNSCB, CN193 (Relay connector), CN167 of PS112, and the wiring. Then repair it when there is any abnormality.
- Check the IO Check (72-30) of M112 and the coupling of the gear, and repair it when there is any abnormality.
- Check the IO Check (72-24) of PS112 or the operation, and repair it when there is any abnormality.
- Replace PS112.
- Replace M112.
- Replace FNSCB.
Faulty part isolation DIPSW
DIPSW6-3
Control during the detachment
The use of the staple is unavailable.