Error Code: C-1115 Follow
Classification
FS: SD-510 abnormality
Cause
The 1st folding knife home sensor (PS110) does not become active within a specified period of time after the 1st folding knife motor (M107) becomes active.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- FNS control board (FNSCB)
- SD control board (SDCB)
- 1st folding knife motor (M107)
- 1st folding knife home sensor (PS110)
Correction
Press the help key to activate and deactivate the sub power switch (SW2) of the main body.
Note
- When you isolate the faulty part, the limited use is available.
- The message "Please call service" and "Press [Help] to disengage" are displayed alternately on the touch panel.
- When you press the help key, the message "Please turn on power again" is displayed on the touch panel.
Solution
- Check the half-fold and the fold & staple and the tri-fold section, and repair it when there is any abnormality.
- Check the connector connection between FNSCB and SDCB, CN52 of FNSCB, CN46 (Relay connector), CN483 (Relay connector), CN401 of SDCB, and the wiring. Then, repair it when there is any abnormality.
- Check the connector connection between SDCB and M107, CN402 of SDCB, CN427 of M107, and the wiring. Then, repair it when there is any abnormality.
- Check the connector connection between SDCB and PS110, CN402 of SDCB, CN460 of PS110, and the wiring. Then, repair it when there is any abnormality.
- Check the IO Check (72-56) of M107 and the coupling of the gear, and repair it when there is any abnormality.
- Check the IO Check (72-59) of PS110 or the operation, and repair it when there is any abnormality.
- Replace PS110.
- Replace M107.
- Replace SDCB.
- Replace FNSCB.
Faulty part isolation DIPSW
DIPSW17-1
Control while detached
The use of the half-fold, the fold&staple, and the tri-fold is unavailable.