Error Code: C-1114 Follow
Classification
FS: FS-532 abnormality
Cause
The rewind paddle release home sensor (PS115) does not become active even when a specified period of time elapses after the rewind paddle release motor (M115) starts the home position search operation.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- FNS control board (FNSCB)
- Rewind paddle release home sensor (PS115)
- Rewind paddle release motor (M115)
Correction
Press the help key to activate and deactivate the sub power switch (SW2) of the main body.
Note
- When you isolate the faulty part, the limited use is available.
- The message "Please call service" and "Press [Help] to disengage" are displayed alternately on the touch panel.
- When you press the help key, the message "Please turn on power again" is displayed on the touch panel.
Solution
- Check the stacker section, and clean or repair it when there is any abnormality.
- Check the connector connection between FNSCB and M115, CN27 of FNSCB, CN129 (Relay connector), CN137 of M115, and the wiring. Then repair it when there is any abnormality.
- Check the connector connection between FNSCB and PS115, CN45 of FNSCB, CN194 (Relay connector), CN178 of PS115, and the wiring. Then repair it when there is any abnormality.
- Check the IO Check (72-39) of M115 and the coupling of the gear, and repair it when there is any abnormality.
- Check the IO Check (72-35) of PS115 or the operation, and repair it when there is any abnormality.
- Replace PS115.
- Replace M115.
- Replace FNSCB.
Faulty part isolation DIPSW
DIPSW6-3
Control during the detachment
The use of the staple is unavailable