Error Code: C-111B Follow
Classification
FS: FS-532 abnormality
Cause
The abnormality detection signal (ICP cut out) of the FNS entrance motor (M001) is detected.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- FNS control board (FNSCB)
- FNS entrance motor (M001)
Correction
Press the help key to activate and deactivate the sub power switch (SW2) of the main body.
Note
- When you isolate the faulty part, the limited use is available.
- The message "Please call service" and "Press [Help] to disengage" are displayed alternately on the touch panel.
- When you press the help key, the message "Please turn on power again" is displayed on the touch panel.
Solution
- Check the connector connection between FNSCB and M001, CN26 of FNSCB, CN101 of M001, and the wiring. Then repair it when there is any abnormality.
- Check the IO Check (72-01) and others of M001 and the coupling of the gear, and repair it when there is any abnormality.
- Replace M001.
- Replace FNSCB.
Faulty part isolation DIPSW
DIPSW6-5
Control during the detachment
The use of FS, SD, PK is unavailable.