Error Code: C-111F Follow
Classification
FS: FS-532 abnormality
Cause
The abnormality detection signal (ICP cut out) of the FNS conveyance motor/2 (M005) is detected.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- FNS control board (FNSCB)
- FNS conveyance motor/2 (M005)
Correction
Press the help key to activate and deactivate the sub power switch (SW2) of the main body.
Note
- When you isolate the faulty part, the limited use is available.
- The message "Please call service" and "Press [Help] to disengage" are displayed alternately on the touch panel.
- When you press the help key, the message "Please turn on power again" is displayed on the touch panel.
Solution
- Check the connector connection between FNSCB and M005, CN22 of FNSCB, CN102 of M005, and the wiring. Then repair it when there is any abnormality.
- Check the IO Check (72-02) and others of M005 and the coupling of the gear, and repair it when there is any abnormality.
- Replace M005.
- Replace FNSCB.
Faulty part isolation DIPSW
DIPSW6-5
Control during the detachment
The use of FS, SD, PK is unavailable.