Error Code: C-1137 Follow
Code
C-1137
Classification
FS: FS-532 abnormality
Cause
The conveyance gate home sensor (PS108) does not become active within a specified period of time after the conveyance gate motor (M108) becomes active.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- FNS control board (FNSCB)
- Conveyance gate motor (M108)
- Conveyance gate home sensor (PS108)
Correction
Press the help key to activate and deactivate the sub power switch (SW2) of the main body.
Note
- When you isolate the faulty part, the limited use is available.
- The message "Please call service" and "Press [Help] to disengage" are displayed alternately on the touch panel.
- When you press the help key, the message "Please turn on power again" is displayed on the touch panel.
Solution
- Check the connector connection between FNSCB and M108, CN25 of FNSCB, CN122 of M108, and the wiring. Then repair it when there is any abnormality.
- Check the connector connection between FNSCB and PS108, CN20 of FNSCB, CN171 of PS108, and the wiring. Then repair it when there is any abnormality.
- Check the IO Check (72-33) of M108 and the coupling of the gear, and repair it when there is any abnormality.
- Check the IO Check (72-28) of PS108 or the operation, and repair it when there is any abnormality.
- Replace PS108.
- Replace M108.
- Replace FNSCB.
Faulty part isolation DIPSW
DIPSW6-5
Control during the detachment
The use of FS, SD, PK is unavailable