Error Code: C-114A Follow
Code
C-114A
Classification
FS: SD-510 abnormality
Cause
The 24 V abnormality detection signal (ICP cut out) of the FNS control board (FNSCB) is detected.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- -
Correction
Press the help key to activate and deactivate the sub power switch (SW2) of the main body.
Note
- When you isolate the faulty part, the limited use is available.
- The message "Please call service" and "Press [Help] to disengage" are displayed alternately on the touch panel.
- When you press the help key, the message "Please turn on power again" is displayed on the touch panel.
Solution
- Check the connector connection between the FNS control board (FNSCB) and the SD control board (SDCB), CN52 of FNSCB, CN46 (Relay connector), CN483 (Relay connector), CN401 of SDCB, and the wiring. Then, repair it when there is any abnormality.
- Replace FNSCB.
Faulty part isolation DIPSW
DIPSW17-1
Control while detached
The use of the half-fold, the fold&staple, and the tri-fold is unavailable.