Error Code: C-1141 Follow
Code
C-1141
Classification
FS: FS-532 abnormality
Cause
After the stack assist motor (M107) becomes active, the stack assist home sensor (PS107) does not become active within a specified period of time.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- FNS control board (FNSCB)
- Stack assist motor (M107)
- Stack assist home sensor (PS107)
Correction
Press the help key to activate and deactivate the sub power switch (SW2) of the main body.
Note
- When you isolate the faulty part, the limited use is available.
- The message "Please call service" and "Press [Help] to disengage" are displayed alternately on the touch panel.
- When you press the help key, the message "Please turn on power again" is displayed on the touch panel.
Solution
- Check the connector connection between FNSCB and M107, CN35 of FNSCB, CN135 (Relay connector), CN108 of M107, and the wiring. Then repair it when there is any abnormality.
- Check the connector connection between FNSCB and PS107, CN45 of FNSCB, CN194 (Relay connector), CN151 of PS107, and the wiring. Then repair it when there is any abnormality.
- Check the IO Check (72-08) of M107 and the coupling of the gear, and repair it when there is any abnormality.
- Check the IO Check (72-08) of PS107 or the operation, and repair it when there is any abnormality.
- Replace PS107.
- Replace M107.
- Replace FNSCB.
Faulty part isolation DIPSW
DIPSW6-3
Control during the detachment
The use of the staple is unavailable