Error Code: C-1156 Follow
Code
C-1156
Classification
FS: FS-532 abnormality
Cause
After the stacker rear stopper motor (M113) becomes active, the stacker rear stopper home sensor (PS113) does not become active within a specified period of time.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- FNS control board (FNSCB)
- Stacker rear stopper motor (M113)
- Stacker rear stopper home sensor (PS113)
Correction
Press the help key to activate and deactivate the sub power switch (SW2) of the main body.
Note
- When you isolate the faulty part, the limited use is available.
- The message "Please call service" and "Press [Help] to disengage" are displayed alternately on the touch panel.
- When you press the help key, the message "Please turn on power again" is displayed on the touch panel.
Solution
- Check the connector connection between FNSCB and M113, CN30 of FNSCB, CN133 (Relay connector), CN199 of M113, and the wiring. Then repair it when there is any abnormality.
- Check the connector connection between FNSCB and PS113, CN44 of FNSCB, CN193 (Relay connector), CN202 (Relay connector), CN169 of PS113, and the wiring. Then repair it when there is any abnormality.
- Check the IO Check (72-31) of M113 and the coupling of the gear, and repair it when there is any abnormality.
- Check the IO Check (72-26) of PS113 or the operation, and repair it when there is any abnormality.
- Replace PS113.
- Replace M113.
- Replace FNSCB.
Faulty part isolation DIPSW
DIPSW6-3
Control during the detachment
The use of the staple is unavailable