Error Code: C-1174 Follow
Code
C-1174
Classification
FS: SD-510 abnormality
Cause
The operation does not complete within a specified period of time after the SD stapler motor (M102) starts the operation.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- FNS control board (FNSCB)
- SD control board (SDCB)
- SD stapler motor (M102)
Correction
Press the help key to activate and deactivate the sub power switch (SW2) of the main body.
Note
- When you isolate the faulty part, the limited use is available.
- The message "Please call service" and "Press [Help] to disengage" are displayed alternately on the touch panel.
- When you press the help key, the message "Please turn on power again" is displayed on the touch panel.
Solution
- Check the connector connection between FNSCB and SDCB, CN52 of FNSCB, CN46 (Relay connector), CN483 (Relay connector), CN401 of SDCB, and the wiring. Then, repair it when there is any abnormality.
- Check the connector connection between SDCB and M102, CN407 of FNSCB, CN486 (Relay connector), CN422 of M102, and the wiring. Then, repair it when there is any abnormality.
- Check the IO Check (72-51) of M102 and the coupling of the gear, and repair it when there is any abnormality.
- Replace M102.
- Replace SDCB.
- Replace FNSCB.
Faulty part isolation DIPSW
DIPSW17-1
Control while detached
The use of the half-fold, the fold&staple, and the tri-fold is unavailable.