Error Code: C-1154 Follow
Code
C-1154
Classification
FS: FS-532 abnormality
Cause
After the gripper exit motor/Up (M104) becomes active, the gripper home sensor/Up (PS104) does not become active within a specified period of time.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- FNS control board (FNSCB)
- Gripper exit motor/Up (M104)
- Gripper home sensor/Up (PS104)
Correction
Press the help key to activate and deactivate the sub power switch (SW2) of the main body.
Note
- When you isolate the faulty part, the limited use is available.
- The message "Please call service" and "Press [Help] to disengage" are displayed alternately on the touch panel.
- When you press the help key, the message "Please turn on power again" is displayed on the touch panel.
Solution
- Check the connector connection between FNSCB and M104, CN27 of FNSCB, CN76 (Relay connector), CN116 of M104, and the wiring. Then repair it when there is any abnormality.
- Check the connector connection between FNSCB and PS104, CN49 of FNSCB, CN75 (Relay connector), CN164 of PS104, and the wiring. Then repair it when there is any abnormality.
- Check the IO Check (72-27) of M104 and the coupling of the gear, and repair it when there is any abnormality.
- Check the IO Check (72-21) of PS104 or the operation, and repair it when there is any abnormality.
- Replace PS104.
- Replace M104.
- Replace FNSCB.
Faulty part isolation DIPSW
DIPSW6-4
Control during the detachment
FS main tray and stapling are not available