Error Code: C-1158 Follow
Code
C-1158
Classification
FS: FS-532 abnormality
Cause
After the roller pressure motor (M110) becomes active, the roller pressure motor home sensor (PS110) does not become active within a specified period of time.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- FNS control board (FNSCB)
- Roller pressure motor (M110)
- Roller pressure motor home sensor (PS110)
Correction
Press the help key to activate and deactivate the sub power switch (SW2) of the main body.
Note
- When you isolate the faulty part, the limited use is available.
- The message "Please call service" and "Press [Help] to disengage" are displayed alternately on the touch panel.
- When you press the help key, the message "Please turn on power again" is displayed on the touch panel.
Solution
- Check the connector connection between FNSCB and M110, CN35 of FNSCB, CN135 (Relay connector), CN123 of M110, and the wiring. Then repair it when there is any abnormality.
- Check the connector connection between FNSCB and PS110, CN45 of FNSCB, CN194 (Relay connector), CN174 of PS110, and the wiring. Then repair it when there is any abnormality.
- Check the IO Check (72-38) of M110 and the coupling of the gear, and repair it when there is any abnormality.
- Check the IO Check (72-31) of PS110 or the operation, and repair it when there is any abnormality.
- Replace PS110.
- Replace M110.
- Replace FNSCB.
Faulty part isolation DIPSW
DIPSW6-3
Control during the detachment
The use of the staple is unavailable