Error Code: C-1159 Follow
Code
C-1159
Classification
FS: FS-532 abnormality
Cause
The bypass gate home sensor (PS109) does not become active within a specified period of time after the bypass gate motor (M109) becomes active.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- FNS control board (FNSCB)
- Bypass gate motor (M109)
- Bypass gate home sensor (PS109)
Correction
Press the help key to activate and deactivate the sub power switch (SW2) of the main body.
Note
- When you isolate the faulty part, the limited use is available.
- The message "Please call service" and "Press [Help] to disengage" are displayed alternately on the touch panel.
- When you press the help key, the message "Please turn on power again" is displayed on the touch panel.
Solution
- Check the connector connection between FNSCB and M109, CN25 of FNSCB, CN125 of M109, and the wiring. Then repair it when there is any abnormality.
- Check the connector connection between FNSCB and PS109, CN20 of FNSCB, CN176 of PS109, and the wiring. Then repair it when there is any abnormality.
- Check the IO Check (72-36) of M109 and the coupling of the gear, and repair it when there is any abnormality.
- Check the IO Check (72-33) of PS109 or the operation, and repair it when there is any abnormality.
- Replace PS109.
- Replace M109.
- Replace FNSCB.
Faulty part isolation DIPSW
DIPSW6-3, DIPSW17-1
Control during the detachment
The use of the staple, the half-fold, the fold&staple, and the tri-fold is unavailable.