Error Code: C-1175 Follow
Code
C-1175
Classification
FS: SD-510 abnormality
Cause
After the stopper motor (M105) becomes active, the stopper home sensor (PS107) does not become active within a specified period of time.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- FNS control board (FNSCB)
- SD control board (SDCB)
- Stopper motor (M105)
- Stopper home sensor (PS107)
Correction
Press the help key to activate and deactivate the sub power switch (SW2) of the main body.
Note
- When you isolate the faulty part, the limited use is available.
- The message "Please call service" and "Press [Help] to disengage" are displayed alternately on the touch panel.
- When you press the help key, the message "Please turn on power again" is displayed on the touch panel.
Solution
- Check the connector connection between FNSCB and SDCB, CN52 of FNSCB, CN46 (Relay connector), CN483 (Relay connector), CN401 of SDCB, and the wiring. Then, repair it when there is any abnormality.
- Check the connector connection between SDCB and M105, CN405 of SDCB, CN425 of M105, and the wiring. Then, repair it when there is any abnormality.
- Check the connector connection between SDCB and PS107, CN415 of SDCB, CN457 of PS107, and the wiring. Then, repair it when there is any abnormality.
- Check the IO Check (72-54) of M105 and the coupling of the gear, and repair it when there is any abnormality.
- Check the IO Check (72-56) of PS107 or the operation, and repair it when there is any abnormality.
- Replace PS107.
- Replace M105.
- Replace SDCB.
- Replace FNSCB.
Faulty part isolation DIPSW
DIPSW17-1
Control while detached
The use of the half-fold, the fold&staple, and the tri-fold is unavailable.