Error Code: C-1181 Follow
Code
C-1181
Classification
FS: SD-510 abnormality
Cause
After the lower paddle motor (M109) becomes active, the lower paddle home sensor (PS114) does not become active within a specified period of time.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- FNS control board (FNSCB)
- SD control board (SDCB)
- Lower paddle motor (M109)
- Lower paddle home sensor (PS114)
Correction
Press the help key to activate and deactivate the sub power switch (SW2) of the main body.
Note
- When you isolate the faulty part, the limited use is available.
- The message "Please call service" and "Press [Help] to disengage" are displayed alternately on the touch panel.
- When you press the help key, the message "Please turn on power again" is displayed on the touch panel.
Solution
- Check the connector connection between FNSCB and SDCB, CN52 of FNSCB, CN46 (Relay connector), CN483 (Relay connector), CN401 of SDCB, and the wiring. Then, repair it when there is any abnormality.
- Check the connector connection between SDCB and M109, CN415 of SDCB, CN429 of M109, and the wiring. Then, repair it when there is any abnormality.
- Check the connector connection between SDCB and PS114, CN415 of SDCB, CN488 (Relay connector), CN454 of PS114, and the wiring. Then, repair it when there is any abnormality.
- Check the IO Check (72-58) of M109 and the coupling of the gear, and repair it when there is any abnormality.
- Check the IO Check (72-58) of PS114 or the operation, and repair it when there is any abnormality.
- Replace PS114.
- Replace M109.
- Replace SDCB.
- Replace FNSCB.
Faulty part isolation DIPSW
DIPSW17-1
Control while detached