Error Code: C-1442 Follow
Code
C-1442
Classification
FS: FS-532/SD-510 abnormality
Cause
Communication error between FS-532 and SD-510.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- FNS control board (FNSCB)
- SD control board (SDCB)
Correction
Press the help key to activate and deactivate the sub power switch (SW2) of the main body.
Note
- When you isolate the faulty part, the limited use is available.
- The message "Please call service" and "Press [Help] to disengage" are displayed alternately on the touch panel.
- When you press the help key, the message "Please turn on power again" is displayed on the touch panel.
Solution
- Deactivate the sub power switch, and then deactivate the main power switch. Then unplug all the power plug of the main body and the options. Restart the main body after 10 seconds.
- Check the connector connection and the wiring between the main body and each option, and repair it when there is any abnormality.
- Check the connector connection between FNSCB and SDCB, CN52 of FNSCB, CN56 (Relay connector), CN53, CN57 (Relay connector), CN400 and CN401 of SDCB, and the wiring. Then, repair it when there is any abnormality.
- Rewrite the firmware of the option.
- Replace SDCB.
- Replace FNSCB.
Faulty part isolation DIPSW
DIPSW17-1
Control while detached
The use of the half-fold, the fold&staple, and the tri-fold is unavailable.