Error Code: C-1480 Follow
Code
C-1480
Classification
Main body: Charging control unit abnormality
Cause
The error detection signal is detected continuously for a specified period of time during output with high voltage source.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- High voltage unit/3 (HV3)
Correction
Press the help key to activate and deactivate the sub power switch (SW2) of the main body.
Note
- When you isolate the faulty part, the limited use is available.
- The message "Please call service" and "Press [Help] to disengage" are displayed alternately on the touch panel.
- When you press the help key, the message "Please turn on power again" is displayed on the touch panel.
Solution
- Check the connection of the high voltage contact of HV3, and clean or repair it when there is any abnormality.
- Check the neutralizing parts, and clean or replace them if there is a dirt or any abnormality.
- Check the connector connection between HV3 and the downstream option, and the wiring. Then repair it when there is any abnormality.
Faulty part isolation DIPSW
DIPSW35-7
Control during the detachment
High voltage power of the electric charge control unit is unavailable.