Error Code: C-2202 Follow
Code
C-2202
Classification
Main body: Developing motor/M abnormality
Cause
When the developing motor/M (M6) is active, an error detection signal of M6 is detected continuously for a specified period of time.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Printer control board (PRCB)
- Developing motor/M (M6)
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
- Check the connector connection between PRCB and M6, and the wiring. Then repair it when there is any abnormality.
- Check the IO Check (50-05) of the M6 and the coupling of the gear, and repair or replace it when there is any abnormality. (Wiring diagram: Main body (2/5): 19-E)
- Replace M6 and PRCB.
Faulty part isolation DIPSW
Control during the detachment