Error Code: C-2201 Follow
Code
C-2201
Classification
Main body: Developing motor/Y abnormality
Cause
When the developing motor/Y (M5) is active, an error detection signal of M5 is detected continuously for a specified period of time.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Printer control board (PRCB)
- Developing motor/Y (M5)
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
- Check the connector connection between PRCB and M5, and the wiring. Then repair it when there is any abnormality.
- Check the IO Check (50-00) of the M5 and the coupling of the gear, and repair or replace it when there is any abnormality. (Wiring diagram: Main body (2/5): 20-E)
- Replace M5 and PRCB.
Faulty part isolation DIPSW
Control during the detachment