Error Code: C-2303* Follow
Code
C-2303*
Classification
Main body: Fan abnormality
Cause
When the transfer belt fan (FM17) is active, an error detection signal of FM17 is detected continuously for a specified period of time.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Printer control board (PRCB)
- Transfer belt fan (FM17)
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
- Check the connector connection between PRCB and FM17, and the wiring. Then repair it when there is any abnormality.
- Rotate FM17 by hand or the IO Check (42-10). Then repair or replace it when there is any abnormality. (Wiring diagram: Main body (2/5): 15-I)
- Replace FM17.
- Replace PRCB.
Faulty part isolation DIPSW
Control during the detachment