Error Code: C-2306* Follow
Code
C-2306*
Classification
Main body: Fan abnormality
Cause
When the drum motor cooling fan/2 (FM7) is active, an error detection signal of FM7 is detected continuously for a specified period of time.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Printer control board (PRCB)
- Drum motor cooling fan/2 (FM7)
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
- Check the connector connection between PRCB and FM7, and the wiring. Then repair it when there is any abnormality.
- Rotate FM7 by hand or the IO Check (42-09). Then repair or replace it when there is any abnormality. (Wiring diagram: Main body (2/5): 8-I)
- Replace FM7.
- Replace PRCB.
Faulty part isolation DIPSW
Control during the detachment