Error Code: C-2444 Follow
Code
C-2444
Classification
Main body: TCR sensor/K initial adjustment abnormality (high density)
Cause
When the initial adjustment is performed with the TCR sensor/K (TCRS3), the output value of TCRS3 exceeds the prescribed value.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Printer control board (PRCB)
- Developing motor/K (M8)
- TCR sensor/K (TCRS3)
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
- Check that the process unit is correctly installed without looseness, and reinstall or repair it when there is any abnormality.
- Check TCRS3, and clean or repair it when there is dirt or any abnormality. (Wiring diagram: Main body (2/5): 23-F)
- Check the developing section, and clean or repair it if there is a sensor dirt or any abnormality.
- Check the connector connection between PRCB and TCRS3, and the wiring. Then repair it when there is any abnormality.
- Check the connector connection between PRCB and M8, and the wiring. Then repair it when there is any abnormality.
- Rotate M8 with the IO Check (50-15) and other method. Then repair or replace it when there is any abnormality. (Wiring diagram: Main body (2/5): 18-E)
- Replace TCRS4.
- Replace M8.
- Replace PRCB.
Faulty part isolation DIPSW
Control during the detachment