Error Code: C-2701 Follow
Code
C-2701
Classification
Main body: High voltage unit/1 abnormality
Cause
An error detection signal of the charging corona/Y is detected while the charging corona/Y is activated. The signal is detected even after you activate and deactivate the charging corona/Y for a prescribed time.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- High voltage unit/1 (HV1)
- Charging corona/Y
- Printer control board (PRCB)
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
- Check the connection of the high voltage contact of the process unit, and clean or repair it when there is any abnormality.
- Check the charger (charging wire and the grid), and clean or repair it if there is any dirt or abnormality.
- Check the connector connection between HV1 and the charger, and the wiring. Then repair it when there is any abnormality. (Wiring diagram: Main body (3/5): 3-M)
- Check the connector connection between PRCB and HV1, and the wiring. Then repair it when there is any abnormality. (Wiring diagram: Main body (3/5): 3-M)
- Replace HV1.
- Replace PRCB.
Faulty part isolation DIPSW