Error Code: C-2431 Follow
Code
C-2431
Classification
Main body: TCR sensor/Y initial adjustment abnormality (low density)
Cause
When the initial adjustment is performed with the TCR sensor/Y (TCRS1), the output value of TCRS1 lowers the prescribed value.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Printer control board (PRCB)
- Developing motor/Y (M5)
- TCR sensor/Y (TCRS1)
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
- Check that the process unit is correctly installed without looseness, and reinstall or repair it when there is any abnormality.
- Check TCRS1, and clean or repair it when there is dirt or any abnormality. (Wiring diagram: Main body (2/5): 22-F)
- Check the developing section, and clean or repair it if there is a sensor dirt or any abnormality.
- Check the connector connection between PRCB and TCRS1, and the wiring. Then repair it when there is any abnormality.
- Check the connector connection between PRCB and M5, and the wiring. Then repair it when there is any abnormality.
- Rotate M5 by IO Check (50-00) and others, and repair or replace it when there is any abnormality. (Wiring diagram: Main body (2/5): 20-E)
- Replace TCRS1.
- Replace M5.
- Replace PRCB.
Faulty part isolation DIPSW
Control during the detachment