Error Code: C-2442 Follow
Code
C-2442
Classification
Main body: TCR sensor/M initial adjustment abnormality (high density)
Cause
When the initial adjustment is performed with the TCR sensor/M (TCRS2), the output value of TCRS2 exceeds the prescribed value.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Printer control board (PRCB)
- Developing motor/M (M6)
- TCR sensor/M (TCRS2)
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
- Check that the process unit is correctly installed without looseness, and reinstall or repair it when there is any abnormality.
- Check TCRS2, and clean or repair it when there is dirt or any abnormality. (Wiring diagram: Main body (2/5): 23-F)
- Check the developing section, and clean or repair it if there is a sensor dirt or any abnormality.
- Check the connector connection between PRCB and TCRS2, and the wiring. Then repair it when there is any abnormality.
- Check the connector connection between PRCB and M6, and the wiring. Then repair it when there is any abnormality.
- Rotate M6 with the IO Check (50-05) and other method. Then repair or replace it when there is any abnormality. (Wiring diagram: Main body (2/5): 19-E)
- Replace TCRS2.
- Replace M6.
- Replace PRCB.
Faulty part isolation DIPSW
Control during the detachment